Schneider Acti9 iK60N MCB 32 Amp 1P C-Curve 6kA A9K24132 is an option among MCB circuit breakers at Bashiti Stores, designed to protect circuits from overloads and short circuits. In this version, the rated current is 32 Amps and it has 1 pole. These specifications distinguish this model from other alternatives in the same series; match them with your circuit requirements and do not choose a higher amperage breaker just to increase the operating margin.
Practical Benefits
- Combines overload and short-circuit protection functions in a single standard device.
- Distributing protection across independent circuits helps organize the distribution board and identify the affected circuit in the event of a fault.
- Selecting the correct current, number of poles, and tripping curve provides the basis for aligning the breaker with circuit requirements.
Technical Specifications for this Model
| Brand |
Schneider Electric |
| Series |
Acti9 iK60N |
| Model Reference |
A9K24132 |
| Rated Current |
32 A |
| Number of Poles |
1P |
| Tripping Curve |
C |
| Breaking Capacity (according to source) |
6kA |
| Rated Operating Voltage |
230VAC |
| Dimensions: W x H x D |
18 x 85 x 78.5 mm |
| Mounting |
DIN rail |
Who Needs This Product?
Electricians, installation contractors, and home or shop owners who are setting up a new distribution board or replacing a breaker that matches an existing circuit. Selection depends on the circuit design, cable cross-section, and installation method, not just the device type or appearance alone.
Installation and Verification Procedure — For Authorized Technicians
The following steps outline the general workflow. Refer to the manufacturer's diagram for reference A9K24132 to identify terminals and tightening torque values. Do not work on a live circuit.
- The technician must disconnect all power sources, secure them against accidental restart, and verify the absence of voltage using an appropriate tool.
- Match the device reference, number of poles, current, and voltage with the board diagram, and check the conductor cross-section and protection coordination.
- Mount the device on the rail or its designated position after ensuring compatibility, and identify the supply and output based on the manufacturer's diagram for this reference.
- Carry out connections according to the tightening torque, stripping length, and wire gauges specified in the model manual; do not use values from a similar device.
- Check the tightness of connections, close the covers, and perform the required operational and protection tests before handing over the circuit.
Frequently Asked Questions Before Buying
Does this breaker protect against earth leakage?
An MCB is designed for overload and short-circuit protection and does not replace earth leakage protection. Check if an RCCB or RCBO is required in your board design.
Should I replace a breaker that trips frequently with one of a higher amperage?
No. You must first identify the cause of the tripping and inspect the load, cables, and connections. Increasing the amperage without analysis may leave the wires without proper protection.
What is the difference between current (Amps) and breaking capacity?
Amperage is the rated current of the breaker, while breaking capacity describes the level of short-circuit current it can interrupt under specified voltage and standard conditions. Do not substitute one for the other.
Schneider at Bashiti Stores — Electrical Department
Choose MCB circuit breakers from the Bashiti Electrical Department according to the specifications required for your project in Jordan. The series name and reference A9K24132 help you identify the part accurately when inquiring or ordering a replacement. At Bashiti Stores, we provide key selection data so you can compare similar products and prepare your order for your technician or contractor based on function and compatibility, rather than just price or appearance.