{"product_id":"bashiti-schneider-00206446","title":"Schneider Acti9 iSW 40A 2P Electrical Isolator Switch A9S65240","description":"\u003cdiv dir=\"ltr\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eSchneider Acti9 iSW 40A 2P Electrical Isolator Switch A9S65240\u003c\/strong\u003e is an option among the isolator switches at Bashiti Stores, intended for manual control and power disconnection for isolation purposes according to the circuit diagram. Check the details of this reference when comparing with similar devices, as functionality and rating are the basis for selecting the correct replacement.\u003c\/p\u003e\n\n\u003ch2\u003ePractical Benefits\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eProvides a clear disconnection and isolation function within panel organization.\u003c\/li\u003e\n\n\u003cli\u003eThe arrangement of the isolation point assists in maintenance planning and handling system components.\u003c\/li\u003e\n\n\u003cli\u003eComparison is based on current, number of poles, and voltage rather than just outward appearance.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications for this Model\u003c\/h2\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eBrand\u003c\/th\u003e\n\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eSeries\u003c\/th\u003e\n\n\u003ctd\u003eActi9 iSW\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eModel Reference\u003c\/th\u003e\n\n\u003ctd\u003eA9S65240\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eRated Current\u003c\/th\u003e\n\n\u003ctd\u003e40 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\n\u003ctd\u003e2P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eRated Operational Voltage\u003c\/th\u003e\n\n\u003ctd\u003e415VAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eDimensions: W x H x D\u003c\/th\u003e\n\n\u003ctd\u003e36 x 85 x 73 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eMounting\u003c\/th\u003e\n\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch2\u003eWho needs this product?\u003c\/h2\u003e\n\n\u003cp\u003eInstallation and maintenance technicians who need a disconnection and isolation point within an electrical panel. Its selection is coordinated with breakers that provide fault protection, and with the circuit voltage, required current, and number of poles.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and Verification — For the Qualified Technician\u003c\/h2\u003e\n\n\u003cp\u003eThe following steps outline the general workflow; the manufacturer's diagram for reference A9S65240 must be used to determine terminals and torque values. Work must not be performed on a circuit connected to power.\u003c\/p\u003e\n\n\u003col\u003e\n\n\u003cli\u003eThe technician disconnects all power sources, secures them against accidental restart, and verifies the absence of voltage with an appropriate tool.\u003c\/li\u003e\n\n\u003cli\u003eThe technician matches the device reference, number of poles, current, and voltage with the panel diagram, and reviews conductor cross-sections and protection coordination.\u003c\/li\u003e\n\n\u003cli\u003eThe unit is mounted on the rail or its designated position after ensuring compatibility, and the supply and output are identified from the manufacturer's diagram for this reference.\u003c\/li\u003e\n\n\u003cli\u003eConnections are made using the tightening torque, stripping length, and wire gauges specified in the model manual; these values must not be transferred from a similar device.\u003c\/li\u003e\n\n\u003cli\u003eCheck the tightness of the installation and connections, close the covers, and conduct the required operational and protection tests before commissioning the circuit.\u003c\/li\u003e\n\n\n\u003c\/ol\u003e\n\n\u003ch2\u003eFrequently Asked Questions Before Buying\u003c\/h2\u003e\n\n\u003ch3\u003eIs the isolator switch an automatic protection breaker?\u003c\/h3\u003e\n\n\u003cp\u003eNo. The function of this product is isolation and control, not automatic disconnection for overload or short circuits. Fault protection is provided by a separate, appropriate device.\u003c\/p\u003e\n\n\u003ch3\u003eIs setting the switch to OFF enough to start maintenance?\u003c\/h3\u003e\n\n\u003cp\u003eAll power sources must be isolated, the absence of voltage verified, and isolation locked out according to site procedures; the position of the handle alone is not a substitute for verification.\u003c\/p\u003e\n\n\u003ch3\u003eHow do I choose the number of poles?\u003c\/h3\u003e\n\n\u003cp\u003eIt is determined by the supply diagram and conductor disconnection requirements, and must be reviewed by the technician responsible for the panel.\u003c\/p\u003e\n\n\u003ch2\u003eSchneider at Bashiti Stores — Electrical Department\u003c\/h2\u003e\n\n\u003cp\u003eChoose isolator switches from the electrical department at Bashiti according to the specifications required for your project in Jordan. The series name and A9S65240 reference help you identify the item accurately when inquiring or ordering a replacement. At Bashiti Stores, we present the essential selection data to help you compare similar products and prepare your order for the technician or electrical contractor based on functionality and compatibility, rather than just price or appearance.\u003c\/p\u003e\n\n\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54699138842897,"sku":"00206446","price":10.71,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/0975\/8481\/files\/00206446.jpg?v=1789809632","url":"https:\/\/www.ammanhardware.com\/en\/products\/bashiti-schneider-00206446","provider":"Amman Hardware stores","version":"1.0","type":"link"}