{"product_id":"bashiti-schneider-00201663","title":"Schneider Easy9 RCCB 40A 4P 30mA EZ9R36440","description":"\u003cdiv dir=\"ltr\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eSchneider Easy9 40A 4P 30mA RCCB EZ9R36440\u003c\/strong\u003e is an option among residual current circuit breakers at Bashiti Stores, intended for detecting residual current and disconnecting the circuit when the specified leakage sensitivity is exceeded. This model features a 40-amp rating and 30mA leakage sensitivity. When comparing, distinguish between the current flowing through the device and the leakage value that triggers disconnection, and check the appropriate protection type for the loads.\u003c\/p\u003e\n\n\u003ch2\u003ePractical Benefits\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eAdds earth leakage detection to the protection system when selected and installed correctly.\u003c\/li\u003e\n\n\u003cli\u003eSpecified rated current and leakage sensitivity allow for clear comparison of the device against panel requirements.\u003c\/li\u003e\n\n\u003cli\u003eDifferentiating between protection type and current helps avoid confusion between wiring protection and leakage protection.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications for this Model\u003c\/h2\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eBrand\u003c\/th\u003e\n\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eSeries\u003c\/th\u003e\n\n\u003ctd\u003eEasy9\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eModel Reference\u003c\/th\u003e\n\n\u003ctd\u003eEZ9R36440\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eRated Current\u003c\/th\u003e\n\n\u003ctd\u003e40 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\n\u003ctd\u003e4P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Sensitivity\u003c\/th\u003e\n\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Detection Type\u003c\/th\u003e\n\n\u003ctd\u003eAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eRated Operational Voltage\u003c\/th\u003e\n\n\u003ctd\u003e400VAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eDimensions: W x H x D\u003c\/th\u003e\n\n\u003ctd\u003e72 x 82 x 72 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eMounting\u003c\/th\u003e\n\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch2\u003eWho needs this product?\u003c\/h2\u003e\n\n\u003cp\u003eTechnicians preparing and maintaining distribution boards in buildings, when earth leakage protection is required according to the protection plan. The type, sensitivity, current, and number of poles must be selected in coordination with other breakers and loads.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and Verification Method — For Professional Technicians\u003c\/h2\u003e\n\n\u003cp\u003eThe following steps outline the general work sequence; the manufacturer's diagram for reference EZ9R36440 must be relied upon to determine terminals and connection values. Do not perform work on a circuit connected to a power supply.\u003c\/p\u003e\n\n\u003col\u003e\n\n\u003cli\u003eThe technician disconnects all power sources, secures them against re-energization, and verifies the absence of voltage with an appropriate tool.\u003c\/li\u003e\n\n\u003cli\u003eMatches the device reference, number of poles, current, and voltage with the panel diagram, and reviews conductor cross-section and protection coordination.\u003c\/li\u003e\n\n\u003cli\u003eMounts the unit on the rail or its designated position after ensuring compatibility, and identifies the supply and load side from the manufacturer's diagram for this reference.\u003c\/li\u003e\n\n\u003cli\u003eExecutes connections using the torque, stripping length, and wire cross-sections specified in the model manual; do not carry these values over from a similar device.\u003c\/li\u003e\n\n\u003cli\u003eChecks the tightness of mounting and connections, then closes covers and performs the required operational and protection tests before handing over the circuit.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eFrequently Asked Questions Before Buying\u003c\/h2\u003e\n\n\u003ch3\u003eDoes an RCCB protect against overload and short circuits?\u003c\/h3\u003e\n\n\u003cp\u003eAn RCCB does not include overcurrent protection, so it requires coordination with an appropriate circuit breaker or fuse. It should not be used as a substitute for an overload and short-circuit breaker.\u003c\/p\u003e\n\n\u003ch3\u003eDoes 40 amps mean the leakage sensitivity is 40 amps?\u003c\/h3\u003e\n\n\u003cp\u003eNo. The rated current and leakage sensitivity are two different values; the sensitivity here is indicated in milliamperes, while the rated current refers to the current flow through the device.\u003c\/p\u003e\n\n\u003ch3\u003eIs the AC type suitable for all electronic loads?\u003c\/h3\u003e\n\n\u003cp\u003eNot automatically. The technician determines the required protection type according to the potential leakage current waveform and the nature of the loads; some circuits may require a different type.\u003c\/p\u003e\n\n\u003ch2\u003eSchneider at Bashiti Stores — Electrical Department\u003c\/h2\u003e\n\n\u003cp\u003eChoose residual current circuit breakers from Bashiti's electrical department according to the specifications required by your project in Jordan. The series name and reference EZ9R36440 help you identify the item precisely when inquiring or ordering a replacement. At Bashiti Stores, we provide basic selection data to compare similar products, and you prepare your order for the technician or electrical contractor based on function and compatibility, not just price or appearance.\u003c\/p\u003e\n\n\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54699139367185,"sku":"00201663","price":57.59,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/0975\/8481\/files\/00201663.jpg?v=1789809635","url":"https:\/\/www.ammanhardware.com\/en\/products\/bashiti-schneider-00201663","provider":"Amman Hardware stores","version":"1.0","type":"link"}