{"product_id":"bashiti-schneider-00201662","title":"Schneider Easy9 RCCB 25A 4P 30mA EZ9R36425","description":"\u003cdiv dir=\"ltr\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eSchneider Easy9 RCCB 25A 4P 30mA EZ9R36425\u003c\/strong\u003e is an option among the earth leakage circuit breakers at Beshaiti Stores, intended for detecting residual current and disconnecting the circuit when the specified leakage sensitivity is exceeded. This model features a 25A current rating and 30mA leakage sensitivity. When comparing, distinguish between the current passing through the device and the leakage value that triggers disconnection, and review the appropriate protection type for the loads.\u003c\/p\u003e\n\n\u003ch2\u003ePractical Benefits\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eAdds earth leakage detection functionality to the protection system when selected and installed correctly.\u003c\/li\u003e\n\n\u003cli\u003eThe presence of a specific rated current and leakage sensitivity allows for clear comparison of the device with panel requirements.\u003c\/li\u003e\n\n\u003cli\u003eDistinguishing between protection type and current helps avoid confusion between wiring protection and leakage protection.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications for this Model\u003c\/h2\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eBrand\u003c\/th\u003e\n\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eSeries\u003c\/th\u003e\n\n\u003ctd\u003eEasy9\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eModel Reference\u003c\/th\u003e\n\n\u003ctd\u003eEZ9R36425\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eRated Current\u003c\/th\u003e\n\n\u003ctd\u003e25 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\n\u003ctd\u003e4P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Sensitivity\u003c\/th\u003e\n\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Detection Type\u003c\/th\u003e\n\n\u003ctd\u003eAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eStated Operating Voltage\u003c\/th\u003e\n\n\u003ctd\u003e400VAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eDimensions: W × H × D\u003c\/th\u003e\n\n\u003ctd\u003e72 × 82 × 72 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eStated Mounting\u003c\/th\u003e\n\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch2\u003eWho Needs This Product?\u003c\/h2\u003e\n\n\u003cp\u003eTechnicians involved in the assembly and maintenance of building distribution boards, when earth leakage protection functionality is required according to the protection plan. The type, sensitivity, current, and number of poles must be selected in coordination with the rest of the breakers and loads.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and Verification Method — For Professional Technicians\u003c\/h2\u003e\n\n\u003cp\u003eThe following steps outline the general work sequence. Use the manufacturer's diagram for the EZ9R36425 reference to determine terminals and connection values. Work must not be performed on a circuit connected to power.\u003c\/p\u003e\n\n\u003col\u003e\n\n\u003cli\u003eThe technician disconnects all power sources and secures them against accidental restart, then verifies the absence of voltage using an appropriate tool.\u003c\/li\u003e\n\n\u003cli\u003eMatches the device reference, number of poles, current, and voltage with the panel diagram, and reviews conductor cross-sections and protection coordination.\u003c\/li\u003e\n\n\u003cli\u003eMounts the unit on the rail or its designated position after ensuring compatibility, and identifies the supply and output from the manufacturer's diagram for this reference.\u003c\/li\u003e\n\n\u003cli\u003eExecutes connections using the torque, stripping length, and wire gauges specified in the model manual; do not carry over these values from a similar device.\u003c\/li\u003e\n\n\u003cli\u003eChecks for firm installation and connection, then closes the covers and performs the required functional and protection tests before handing over the circuit.\u003c\/li\u003e\n\n\n\u003c\/ol\u003e\n\n\u003ch2\u003eFAQs Before Purchasing\u003c\/h2\u003e\n\n\u003ch3\u003eDoes an RCCB protect against overload and short circuits?\u003c\/h3\u003e\n\n\u003cp\u003eAn RCCB does not include overcurrent protection; therefore, it requires coordination with an appropriate circuit breaker or fuse. It should not be used as a substitute for an overload and short-circuit breaker.\u003c\/p\u003e\n\n\u003ch3\u003eDoes 40A mean the leakage sensitivity is 40A?\u003c\/h3\u003e\n\n\u003cp\u003eNo. The rated current and leakage sensitivity are two different values; the sensitivity here is specified in milliamperes (mA), while the rated current refers to the current flowing through the device.\u003c\/p\u003e\n\n\u003ch3\u003eIs the AC type suitable for all electronic loads?\u003c\/h3\u003e\n\n\u003cp\u003eNot automatically. The technician determines the required type of protection based on the potential leakage current waveform and the nature of the loads; some circuits may require another type.\u003c\/p\u003e\n\n\u003ch2\u003eSchneider at Beshaiti Stores — Electrical Department\u003c\/h2\u003e\n\n\u003cp\u003eChoose earth leakage circuit breakers from Beshaiti's electrical department according to the specifications required for your project in Jordan. The series name and the EZ9R36425 reference help you identify the item precisely when inquiring or ordering a replacement. At Beshaiti Stores, we provide key selection data so you can compare similar products and prepare your order for a technician or installation contractor based on function and compatibility, not just price or appearance.\u003c\/p\u003e\n\n\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54699139432721,"sku":"00201662","price":53.03,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/0975\/8481\/files\/00201662.jpg?v=1789809635","url":"https:\/\/www.ammanhardware.com\/en\/products\/bashiti-schneider-00201662","provider":"Amman Hardware stores","version":"1.0","type":"link"}