{"product_id":"bashiti-schneider-00201661","title":"Schneider Easy9 RCCB 63A 2P 30mA EZ9R36263","description":"\u003cdiv dir=\"rtl\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eSchneider Easy9 63A 2P 30mA RCCB EZ9R36263\u003c\/strong\u003e is an option among the earth leakage circuit breakers at Beshaiti Stores, designed to detect residual current and disconnect the circuit when the specified leakage sensitivity is exceeded. This model features a 63A current rating and a 30mA leakage sensitivity. When comparing, distinguish between the current passing through the device and the leakage value that triggers disconnection, and review the appropriate type of protection for your loads.\u003c\/p\u003e\n\n\u003ch2\u003ePractical Benefits\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eAdds earth leakage detection to the protection system when selected and installed correctly.\u003c\/li\u003e\n\n\u003cli\u003eSpecific rated current and leakage sensitivity allow for clear comparison of the device with distribution board requirements.\u003c\/li\u003e\n\n\u003cli\u003eDistinguishing between protection type and current helps avoid confusion between wire protection and leakage protection.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications for This Model\u003c\/h2\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eBrand\u003c\/th\u003e\n\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eSeries\u003c\/th\u003e\n\n\u003ctd\u003eEasy9\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eModel Reference\u003c\/th\u003e\n\n\u003ctd\u003eEZ9R36263\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eRated Current\u003c\/th\u003e\n\n\u003ctd\u003e63 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\n\u003ctd\u003e2P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Sensitivity\u003c\/th\u003e\n\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Detection Type\u003c\/th\u003e\n\n\u003ctd\u003eAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eStated Operating Voltage\u003c\/th\u003e\n\n\u003ctd\u003e230VAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eDimensions: W x H x D\u003c\/th\u003e\n\n\u003ctd\u003e36 x 82 x 72 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eMounting\u003c\/th\u003e\n\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch2\u003eWho Needs This Product?\u003c\/h2\u003e\n\n\u003cp\u003eTechnicians involved in the assembly and maintenance of building distribution boards, when earth leakage protection is required according to the protection scheme. The type, sensitivity, current, and number of poles must be selected in coordination with other circuit breakers and loads.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and Verification — For Professional Technicians\u003c\/h2\u003e\n\n\u003cp\u003eThe following steps outline the general workflow. Refer to the manufacturer's diagram for the EZ9R36263 reference to determine terminals and torque values. Never perform work on a live circuit.\u003c\/p\u003e\n\n\u003col\u003e\n\n\u003cli\u003eThe technician disconnects all power sources, secures them against accidental restart, and verifies the absence of voltage with a suitable tool.\u003c\/li\u003e\n\n\u003cli\u003eMatches the device reference, number of poles, current, and voltage with the board diagram, and reviews cable cross-section and protection coordination.\u003c\/li\u003e\n\n\u003cli\u003eInstalls the unit on the rail or its designated position after ensuring compatibility, and identifies the supply and load terminals from the manufacturer's diagram for this reference.\u003c\/li\u003e\n\n\u003cli\u003eExecutes the connections according to the tightening torque, stripping length, and wire sections specified in the model manual; do not transfer these values from a similar device.\u003c\/li\u003e\n\n\u003cli\u003eChecks the security of the mounting and connections, closes the covers, and performs the required functional and protection tests before commissioning the circuit.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\n\u003c\/ol\u003e\n\n\u003ch2\u003eFrequently Asked Questions Before Purchasing\u003c\/h2\u003e\n\n\u003ch3\u003eDoes an RCCB protect against overload and short circuits?\u003c\/h3\u003e\n\n\u003cp\u003eAn RCCB does not provide overcurrent protection, so it requires coordination with a suitable circuit breaker or fuse. It should not be used as a substitute for an overload and short-circuit breaker.\u003c\/p\u003e\n\n\u003ch3\u003eDoes 40A mean the leakage sensitivity is 40A?\u003c\/h3\u003e\n\n\u003cp\u003eNo. The rated current and leakage sensitivity are two different values; the sensitivity here is stated in milliamperes (mA), while the rated current refers to the current flow through the device.\u003c\/p\u003e\n\n\u003ch3\u003eIs the AC type suitable for all electronic loads?\u003c\/h3\u003e\n\n\u003cp\u003eNot automatically. The technician determines the required type of protection based on the potential leakage current waveform and the nature of the loads; some circuits may require a different type.\u003c\/p\u003e\n\n\u003ch2\u003eSchneider at Beshaiti Stores — Electrical Department\u003c\/h2\u003e\n\n\u003cp\u003eChoose earth leakage circuit breakers from Beshaiti's electrical department according to the specifications required for your project in Jordan. The series name and EZ9R36263 reference help you identify the part accurately when inquiring or requesting a replacement. At Beshaiti Stores, we provide essential selection data to help you compare similar products and prepare your order for a technician or contractor based on function and compatibility, rather than just price or appearance.\u003c\/p\u003e\n\n\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54699139531025,"sku":"00201661","price":55.76,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/0975\/8481\/files\/00201661.jpg?v=1789809635","url":"https:\/\/www.ammanhardware.com\/en\/products\/bashiti-schneider-00201661","provider":"Amman Hardware stores","version":"1.0","type":"link"}