{"product_id":"bashiti-schneider-00201660","title":"Schneider Easy9 RCCB 40A 2P 30mA EZ9R36240","description":"\u003cdiv dir=\"ltr\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eSchneider Easy9 RCCB 40A 2P 30mA EZ9R36240\u003c\/strong\u003e is an option among residual current circuit breakers at Bashiti Stores, intended for detecting residual current and disconnecting the circuit when the specified leakage sensitivity is exceeded. This model features a 40A current rating and a 30mA leakage sensitivity. When comparing, distinguish between the current flowing through the device and the leakage value that triggers disconnection, and review the appropriate protection type for the loads.\u003c\/p\u003e\n\n\u003ch2\u003ePractical Benefits\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eAdds residual current detection functionality to the protection system when selected and installed correctly.\u003c\/li\u003e\n\n\u003cli\u003eThe presence of a specific rated current and leakage sensitivity allows for a clear comparison of the device with panel requirements.\u003c\/li\u003e\n\n\u003cli\u003eDistinguishing between protection type and current helps avoid confusion between wire protection and leakage protection.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications for this Model\u003c\/h2\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eBrand\u003c\/th\u003e\n\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eSeries\u003c\/th\u003e\n\n\u003ctd\u003eEasy9\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eModel Reference\u003c\/th\u003e\n\n\u003ctd\u003eEZ9R36240\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eRated Current\u003c\/th\u003e\n\n\u003ctd\u003e40 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\n\u003ctd\u003e2P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Sensitivity\u003c\/th\u003e\n\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Detection Type\u003c\/th\u003e\n\n\u003ctd\u003eAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eRated Operational Voltage\u003c\/th\u003e\n\n\u003ctd\u003e230VAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eDimensions: W x H x D\u003c\/th\u003e\n\n\u003ctd\u003e36 x 82 x 72 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eMounting\u003c\/th\u003e\n\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch2\u003eWho Needs This Product?\u003c\/h2\u003e\n\n\u003cp\u003eTechnicians preparing and maintaining distribution panels in buildings when earth leakage protection is required according to the protection plan. The type, sensitivity, current, and number of poles must be selected in coordination with other breakers and loads.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and Verification Procedure — For Authorized Technicians\u003c\/h2\u003e\n\n\u003cp\u003eThe following steps outline the general workflow; refer to the manufacturer's diagram for the EZ9R36240 reference to determine terminals and tightening values. Do not perform work on a circuit connected to a power supply.\u003c\/p\u003e\n\n\u003col\u003e\n\n\u003cli\u003eThe technician disconnects all power sources and secures them against accidental restart, then verifies the absence of voltage with an appropriate tool.\u003c\/li\u003e\n\n\u003cli\u003eMatches the device reference, number of poles, current, and voltage with the panel diagram, and reviews conductor cross-section and protection coordination.\u003c\/li\u003e\n\n\u003cli\u003eMounts the unit on the rail or its designated position after ensuring compatibility, and identifies the supply and output from the manufacturer's diagram for this reference.\u003c\/li\u003e\n\n\u003cli\u003eExecutes connections with the tightening torque, stripping length, and wire gauges specified in the model manual; do not carry over these values from a similar device.\u003c\/li\u003e\n\n\u003cli\u003eChecks the integrity of mounting and connection, then closes covers and performs required operation and protection tests before handing over the circuit.\u003c\/li\u003e\n\n\u003cli\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eFrequently Asked Questions Before Purchase\u003c\/h2\u003e\n\n\u003ch3\u003eDoes an RCCB protect against overload and short circuits?\u003c\/h3\u003e\n\n\u003cp\u003eAn RCCB does not include overcurrent protection, so it requires coordination with a suitable breaker or fuse. It is not used as a substitute for overload and short-circuit breakers.\u003c\/p\u003e\n\n\u003ch3\u003eDoes 40A mean the leakage sensitivity is 40A?\u003c\/h3\u003e\n\n\u003cp\u003eNo. Rated current and leakage sensitivity are two different values; the sensitivity here is stated in milliamperes (mA), while the rated current concerns the current flowing through the device.\u003c\/p\u003e\n\n\u003ch3\u003eIs the AC type suitable for all electronic loads?\u003c\/h3\u003e\n\n\u003cp\u003eNot automatically. The technician determines the required protection type based on the shape of the potential leakage current and the nature of the loads, and some circuits may require a different type.\u003c\/p\u003e\n\n\u003ch2\u003eSchneider at Bashiti Stores — Electrical Department\u003c\/h2\u003e\n\n\u003cp\u003eChoose residual current circuit breakers from the electrical department at Bashiti according to the specifications required for your project in Jordan. The series name and reference EZ9R36240 help you identify the part accurately when inquiring or ordering a replacement. At Bashiti Stores, we display essential selection data for you to compare similar products and prepare your order for the technician or electrical contractor based on functionality and compatibility, not just on price or appearance.\u003c\/p\u003e\n\n\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54699139596561,"sku":"00201660","price":31.61,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/0975\/8481\/files\/00201060.jpg?v=1789809636","url":"https:\/\/www.ammanhardware.com\/en\/products\/bashiti-schneider-00201660","provider":"Amman Hardware stores","version":"1.0","type":"link"}