{"product_id":"bashiti-schneider-00201582","title":"Schneider Acti9 iID 63A 4P 30mA RCCB A9R41463","description":"\u003cdiv dir=\"ltr\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eSchneider Acti9 iID 63A 4P 30mA RCCB A9R41463\u003c\/strong\u003e is a selection among earth leakage circuit breakers at Beshaiti Stores, designed to detect residual current and trip the circuit when the specified leakage sensitivity is exceeded. This model features a 63A current rating and a 30mA leakage sensitivity. When comparing, distinguish between the current flowing through the device and the leakage value that triggers a trip, and review the appropriate protection type for the loads.\u003c\/p\u003e\n\n\u003ch2\u003ePractical Benefits\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eAdds earth leakage detection to the protection system when correctly selected and installed.\u003c\/li\u003e\n\n\u003cli\u003eThe clear rated current and leakage sensitivity allow for easy comparison with panel requirements.\u003c\/li\u003e\n\n\u003cli\u003eDistinguishing between protection type and current helps avoid confusion between wire protection and leakage protection.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications for this Model\u003c\/h2\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eBrand\u003c\/th\u003e\n\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eSeries\u003c\/th\u003e\n\n\u003ctd\u003eActi9 iID\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eModel Reference\u003c\/th\u003e\n\n\u003ctd\u003eA9R41463\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eRated Current\u003c\/th\u003e\n\n\u003ctd\u003e63 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\n\u003ctd\u003e4P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Sensitivity\u003c\/th\u003e\n\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Detection Type\u003c\/th\u003e\n\n\u003ctd\u003eAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eRated Operational Voltage\u003c\/th\u003e\n\n\u003ctd\u003e380VAC to 415VAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eDimensions: W x H x D\u003c\/th\u003e\n\n\u003ctd\u003e72 × 91 × 73.5 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eMounting\u003c\/th\u003e\n\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch2\u003eWho Needs This Product?\u003c\/h2\u003e\n\n\u003cp\u003eTechnicians involved in the assembly and maintenance of building distribution panels, when an earth leakage protection function is required according to the protection plan. The type, sensitivity, current, and number of poles must be selected in coordination with other circuit breakers and loads.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and Verification Procedure — For Licensed Technicians\u003c\/h2\u003e\n\n\u003cp\u003eThe following steps outline the general workflow. Refer to the manufacturer's diagram for the A9R41463 reference to determine terminal positions and torque values. Do not perform work on a circuit connected to power.\u003c\/p\u003e\n\n\u003col\u003e\n\n\u003cli\u003eThe technician disconnects all power sources, secures them against reactivation, and verifies the absence of voltage with a suitable tool.\u003c\/li\u003e\n\n\u003cli\u003eMatches the device reference, number of poles, current, and voltage with the panel diagram, and reviews conductor cross-section and protection coordination.\u003c\/li\u003e\n\n\u003cli\u003eMounts the unit on the rail or its designated position after confirming compatibility, and identifies the supply and output based on the manufacturer's diagram for this reference.\u003c\/li\u003e\n\n\u003cli\u003eExecutes connections using the torque settings, stripping length, and wire gauges specified in the model manual; do not transpose these values from a similar device.\u003c\/li\u003e\n\n\u003cli\u003eChecks the tightness of the mounting and connections, closes the covers, and performs the required operational and protection tests before handing over the circuit.\u003c\/li\u003e\n\n\n\u003c\/ol\u003e\n\n\u003ch2\u003eFrequently Asked Questions Before Buying\u003c\/h2\u003e\n\n\u003ch3\u003eDoes an RCCB protect against overload and short circuits?\u003c\/h3\u003e\n\n\u003cp\u003eNo, an RCCB does not include overcurrent protection, so it must be coordinated with a suitable circuit breaker or fuse. It is not used as a substitute for an overload and short-circuit breaker.\u003c\/p\u003e\n\n\u003ch3\u003eDoes 40A mean the leakage sensitivity is 40A?\u003c\/h3\u003e\n\n\u003cp\u003eNo. The rated current and leakage sensitivity are different values; the sensitivity here is measured in milliamperes, while the rated current refers to the current capacity of the device.\u003c\/p\u003e\n\n\u003ch3\u003eIs the AC type suitable for all electronic loads?\u003c\/h3\u003e\n\n\u003cp\u003eNot automatically. The technician determines the required protection type based on the potential leakage current waveform and the nature of the loads; some circuits may require a different type.\u003c\/p\u003e\n\n\u003ch2\u003eSchneider at Beshaiti Stores — Electrical Department\u003c\/h2\u003e\n\n\u003cp\u003eChoose earth leakage circuit breakers from the Beshaiti electrical department according to the specifications required for your project in Jordan. The series name and A9R41463 reference help you identify the part accurately when inquiring or ordering a replacement. At Beshaiti Stores, we provide essential selection data to compare similar products, preparing your order for a technician or installation contractor based on function and compatibility, not just price or appearance.\u003c\/p\u003e\n\n\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54699139760401,"sku":"00201582","price":76.49,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/0975\/8481\/files\/00201582.jpg?v=1789809636","url":"https:\/\/www.ammanhardware.com\/en\/products\/bashiti-schneider-00201582","provider":"Amman Hardware stores","version":"1.0","type":"link"}