{"product_id":"bashiti-schneider-00201581","title":"Schneider Acti9 iID K Residual Current Circuit Breaker (RCCB), 40A, 4P, 30mA, A9R50440","description":"\u003cdiv dir=\"ltr\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eSchneider Acti9 iID K RCCB 40 Amp 4P 30mA A9R50440\u003c\/strong\u003e is an option among residual current circuit breakers at Bashiti Stores, intended for residual current detection and circuit disconnection when the specified leakage sensitivity is exceeded. This model features a 40A rated current and 30mA leakage sensitivity. When comparing, distinguish between the current flowing through the device and the leakage value that triggers disconnection, and verify the appropriate protection type for your loads.\u003c\/p\u003e\n\n\u003ch2\u003ePractical Benefits\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eAdds earth leakage detection functionality to the protection system when selected and installed correctly.\u003c\/li\u003e\n\n\u003cli\u003eThe presence of specific rated current and leakage sensitivity allows for clear comparison of the device against panel requirements.\u003c\/li\u003e\n\n\u003cli\u003eDistinguishing between protection type and current helps avoid confusion between wiring protection and leakage protection.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications for this Model\u003c\/h2\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eBrand\u003c\/th\u003e\n\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eSeries\u003c\/th\u003e\n\n\u003ctd\u003eActi9 iID K\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eModel Reference\u003c\/th\u003e\n\n\u003ctd\u003eA9R50440\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eRated Current\u003c\/th\u003e\n\n\u003ctd\u003e40 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\n\u003ctd\u003e4P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Sensitivity\u003c\/th\u003e\n\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Detection Type\u003c\/th\u003e\n\n\u003ctd\u003eAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eStated Operating Voltage\u003c\/th\u003e\n\n\u003ctd\u003e380VAC to 415VAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eDimensions: W x H x D\u003c\/th\u003e\n\n\u003ctd\u003e72 × 85 × 69 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eStated Mounting\u003c\/th\u003e\n\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch2\u003eWho needs this product?\u003c\/h2\u003e\n\n\u003cp\u003eDistribution board installation and maintenance technicians, when earth leakage protection is required according to the protection scheme. The type, sensitivity, current, and number of poles must be selected in coordination with other breakers and loads.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and Verification Procedure — For Authorized Technicians\u003c\/h2\u003e\n\n\u003cp\u003eThe following steps outline the general workflow. Refer to the manufacturer's diagram for reference A9R50440 to determine terminals and connection values. Do not perform work on a circuit connected to a power supply.\u003c\/p\u003e\n\n\u003col\u003e\n\n\u003cli\u003eThe technician disconnects all power sources and secures them against accidental restart, then verifies the absence of voltage with an appropriate tool.\u003c\/li\u003e\n\n\u003cli\u003eChecks the device reference, number of poles, current, and voltage against the panel diagram, and reviews conductor cross-section and protection coordination.\u003c\/li\u003e\n\n\u003cli\u003eInstalls the unit on the DIN rail or its designated position after ensuring compatibility, and identifies supply and output from the manufacturer's diagram for this reference.\u003c\/li\u003e\n\n\u003cli\u003ePerforms connections using the tightening torque, stripping length, and wire gauges specified in the model manual; do not carry these values over from a similar device.\u003c\/li\u003e\n\n\u003cli\u003eInspects the security of the mounting and connections, then closes the covers and conducts the required operational and protection tests before handing over the circuit.\u003c\/li\u003e\n\n\u003cli\u003eCommon Questions Before Purchasing\u003c\/li\u003e\n\n\u003ch3\u003eDoes an RCCB protect against overload and short circuits?\u003c\/h3\u003e\n\n\u003cp\u003eAn RCCB does not include overcurrent protection; therefore, it requires coordination with an appropriate breaker or fuse. It should not be used as a substitute for an overload and short-circuit breaker.\u003c\/p\u003e\n\n\u003ch3\u003eDoes 40 Amp mean the leakage sensitivity is 40 Amps?\u003c\/h3\u003e\n\n\u003cp\u003eNo. The rated current and leakage sensitivity are two different values; sensitivity here is expressed in milliamperes, while the rated current pertains to the current flow through the device.\u003c\/p\u003e\n\n\u003ch3\u003eIs the AC type suitable for all electronic loads?\u003c\/h3\u003e\n\n\u003cp\u003eNot automatically. The technician determines the required protection type based on the potential leakage current waveform and the nature of the loads, as some circuits may require a different type.\u003c\/p\u003e\n\n\u003ch2\u003eSchneider at Bashiti Stores — Electrical Department\u003c\/h2\u003e\n\n\u003cp\u003eChoose residual current circuit breakers from the Bashiti electrical department according to the specifications required for your project in Jordan. The series name and reference A9R50440 help you identify the exact part when inquiring or ordering a replacement. At Bashiti Stores, we provide essential selection data to compare similar products, preparing your order for the technician or electrical contractor based on functionality and compatibility, rather than just price or appearance.\u003c\/p\u003e\n\n\n\u003c\/ol\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54699139727633,"sku":"00201581","price":62.11,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/0975\/8481\/files\/00201581.jpg?v=1789809636","url":"https:\/\/www.ammanhardware.com\/en\/products\/bashiti-schneider-00201581","provider":"Amman Hardware stores","version":"1.0","type":"link"}