{"product_id":"bashiti-schneider-00201580","title":"Schneider Acti9 iID K RCCB Residual Current Circuit Breaker 25A 4P 30mA A9R50425","description":"\u003cdiv dir=\"ltr\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eSchneider Acti9 iID K 25A 4P 30mA RCCB (A9R50425)\u003c\/strong\u003e is an option among residual current circuit breakers at Bashiti Stores, intended for detecting residual current and tripping the circuit when the specified leakage sensitivity is exceeded. This model has a 25A rating and 30mA leakage sensitivity. When comparing, distinguish between the current passing through the device and the leakage value that triggers a trip, and review the appropriate protection type for the loads.\u003c\/p\u003e\n\n\u003ch2\u003ePractical Benefits\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eAdds residual current detection functionality to the protection system when selected and installed correctly.\u003c\/li\u003e\n\n\u003cli\u003eThe presence of a specific rated current and leakage sensitivity allows for clear comparison of the device against panel requirements.\u003c\/li\u003e\n\n\u003cli\u003eDistinguishing between protection type and current helps avoid confusion between wiring protection and leakage protection.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications for This Model\u003c\/h2\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eBrand\u003c\/th\u003e\n\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eSeries\u003c\/th\u003e\n\n\u003ctd\u003eActi9 iID K\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003cth\u003eModel Reference\u003c\/th\u003e\n\n\u003ctd\u003eA9R50425\u003c\/td\u003e\n\n\n\u003ctr\u003e\n\n\u003cth\u003eRated Current\u003c\/th\u003e\n\n\u003ctd\u003e25 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\n\u003ctd\u003e4P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Sensitivity\u003c\/th\u003e\n\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Detection Type\u003c\/th\u003e\n\n\u003ctd\u003eAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eRated Operational Voltage\u003c\/th\u003e\n\n\u003ctd\u003e380VAC to 415VAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eDimensions: W x H x D\u003c\/th\u003e\n\n\u003ctd\u003e72 x 85 x 69 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eMounting\u003c\/th\u003e\n\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch2\u003eWho Needs This Product?\u003c\/h2\u003e\n\n\u003cp\u003eTechnicians preparing and maintaining distribution panels in buildings, when residual current protection is required according to the protection plan. The type, sensitivity, current, and number of poles must be selected in coordination with other breakers and loads.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and Verification — For the Professional Technician\u003c\/h2\u003e\n\n\u003cp\u003eThe following steps outline the general workflow; the manufacturer's diagram for reference A9R50425 must be followed to determine terminals and connection values. Work must not be performed on a live circuit.\u003c\/p\u003e\n\n\u003col\u003e\n\n\u003cli\u003eThe technician disconnects all power sources and secures them against accidental restart, then verifies the absence of voltage with a suitable tool.\u003c\/li\u003e\n\n\u003cli\u003eMatches the device reference, number of poles, current, and voltage with the panel diagram, and reviews conductor cross-sections and protection coordination.\u003c\/li\u003e\n\n\u003cli\u003eMounts the component on the rail or its designated position after ensuring compatibility, and identifies supply and output from the manufacturer's diagram for this reference.\u003c\/li\u003e\n\n\u003cli\u003ePerforms connections according to the tightening torque, stripping length, and wire cross-sections specified in the model manual; these values should not be taken from a similar device.\u003c\/li\u003e\n\n\u003cli\u003eChecks the tightness of the installation and connections, closes the covers, and conducts the required operational and protection tests before handing over the circuit.\u003c\/li\u003e\n\n-\u003c\/ol\u003e\n\n\u003ch2\u003eFrequently Asked Questions Before Purchasing\u003c\/h2\u003e\n\n\u003ch3\u003eDoes an RCCB protect against overload and short circuits?\u003c\/h3\u003e\n\n\u003cp\u003eThe RCCB does not include overcurrent protection, therefore it requires coordination with a suitable circuit breaker or fuse. It should not be used as a substitute for an overload and short-circuit breaker.\u003c\/p\u003e\n\n\u003ch3\u003eDoes 40A mean the leakage sensitivity is 40A?\u003c\/h3\u003e\n\n\u003cp\u003eNo. The rated current and leakage sensitivity are two different values; sensitivity here is indicated in milliamperes (mA), while the rated current concerns the current flow through the device.\u003c\/p\u003e\n\n\u003ch3\u003eIs the AC type suitable for all electronic loads?\u003c\/h3\u003e\n\n\u003cp\u003eNot automatically. The technician determines the required protection type based on the shape of the potential leakage current and the nature of the loads, and some circuits may require a different type.\u003c\/p\u003e\n\n\u003ch2\u003eSchneider at Bashiti Stores — Electrical Department\u003c\/h2\u003e\n\n\u003cp\u003eChoose residual current circuit breakers from the electrical department at Bashiti according to the specifications required for your project in Jordan. The series name and reference A9R50425 help you identify the part accurately when inquiring or requesting a replacement. At Bashiti Stores, we provide key selection data so you can compare similar products and prepare your order for a technician or installation contractor based on function and compatibility, not just on price or appearance.\u003c\/p\u003e\n\n\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54699139825937,"sku":"00201580","price":60.11,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/0975\/8481\/files\/00201580.jpg?v=1789809637","url":"https:\/\/www.ammanhardware.com\/en\/products\/bashiti-schneider-00201580","provider":"Amman Hardware stores","version":"1.0","type":"link"}