{"product_id":"bashiti-schneider-00201567","title":"Schneider Acti9 iID RCCB 63A 2P 30mA A9R41263","description":"\u003cdiv dir=\"ltr\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eSchneider Acti9 iID 63A 2P 30mA RCCB (A9R41263)\u003c\/strong\u003e is an option among residual current circuit breakers at Bashiti Stores, designed to monitor residual current and disconnect the circuit when the specified leakage sensitivity is exceeded. This model features a 63A current rating and 30mA leakage sensitivity. When comparing, distinguish between the current passing through the device and the leakage value that triggers disconnection, and verify the appropriate type of protection for your loads.\u003c\/p\u003e\n\n\u003ch2\u003ePractical Benefits\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eAdds residual current protection functionality to the protection system when selected and installed correctly.\u003c\/li\u003e\n\n\u003cli\u003eThe clear rated current and leakage sensitivity allow for easy comparison of the device with panel requirements.\u003c\/li\u003e\n\n\u003cli\u003eDistinguishing between protection type and current helps avoid confusion between wiring protection and leakage protection.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications for This Model\u003c\/h2\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eBrand\u003c\/th\u003e\n\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eSeries\u003c\/th\u003e\n\n\u003ctd\u003eActi9 iID\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eModel Reference\u003c\/th\u003e\n\n\u003ctd\u003eA9R41263\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eRated Current\u003c\/th\u003e\n\n\u003ctd\u003e63 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\n\u003ctd\u003e2P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Sensitivity\u003c\/th\u003e\n\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Detection Type\u003c\/th\u003e\n\n\u003ctd\u003eAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eStated Operating Voltage\u003c\/th\u003e\n\n\u003ctd\u003e220VAC to 240VAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eDimensions: W x H x D\u003c\/th\u003e\n\n\u003ctd\u003e36 x 91 x 73.5 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eStated Mounting\u003c\/th\u003e\n\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch2\u003eWho Needs This Product?\u003c\/h2\u003e\n\n\u003cp\u003eTechnicians preparing and maintaining distribution boards in buildings when residual current protection is required by the protection scheme. The type, sensitivity, current, and number of poles must be selected in coordination with other circuit breakers and loads.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and Verification — For Qualified Technicians\u003c\/h2\u003e\n\n\u003cp\u003eThe following steps outline the general workflow. Refer to the manufacturer's diagram for the A9R41263 reference to determine terminal assignments and tightening torque. Work must not be performed on a live circuit.\u003c\/p\u003e\n\n\u003col\u003e\n\n\u003cli\u003eThe technician disconnects all power sources, secures them against reactivation, and verifies the absence of voltage with a suitable tool.\u003c\/li\u003e\n\n\u003cli\u003eCheck the device reference, number of poles, current, and voltage against the panel diagram, and review conductor cross-sections and protection coordination.\u003c\/li\u003e\n\n\u003cli\u003eMount the device on the rail or its designated position after ensuring compatibility, and identify input\/output according to the manufacturer's diagram for this reference.\u003c\/li\u003e\n\n\u003cli\u003ePerform connections using the tightening torque, stripping length, and wire gauges specified in the model manual; do not transpose these values from similar devices.\u003c\/li\u003e\n\n\u003cli\u003eCheck the tightness of the mounting and connections, close the covers, and perform the required functional and protection tests before handing over the circuit.\u003c\/li\u003e\n\n\u003cli\u003eFrequently Asked Questions Before Buying\u003c\/li\u003e\n\n\u003ch3\u003eDoes an RCCB protect against overload and short circuits?\u003c\/h3\u003e\n\n\u003cp\u003eAn RCCB does not include overcurrent protection, so it requires coordination with an appropriate circuit breaker or fuse. It should not be used as a substitute for overload and short-circuit protection.\u003c\/p\u003e\n\n\u003ch3\u003eDoes 63A mean the leakage sensitivity is 63A?\u003c\/h3\u003e\n\n\u003cp\u003eNo. The rated current and leakage sensitivity are two different values; the sensitivity here is expressed in milliamperes (mA), while the rated current relates to the current capacity of the device.\u003c\/p\u003e\n\n\u003ch3\u003eIs the AC type suitable for all electronic loads?\u003c\/h3\u003e\n\n\u003cp\u003eNot automatically. The technician determines the required type of protection based on the potential leakage current waveform and the nature of the loads; some circuits may require a different type.\u003c\/p\u003e\n\n\u003ch2\u003eSchneider at Bashiti Stores — Electrical Department\u003c\/h2\u003e\n\n\u003cp\u003eChoose residual current circuit breakers from the Bashiti Electrical Department according to the specifications required by your project in Jordan. The series name and the A9R41263 reference help you identify the item precisely when inquiring or ordering a replacement. At Bashiti Stores, we provide essential selection data to help you compare similar products, preparing your order for the technician or contractor based on function and compatibility, rather than just price or appearance.\u003c\/p\u003e\n\n\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54699139924241,"sku":"00201567","price":63.26,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/0975\/8481\/files\/00201567.jpg?v=1789809637","url":"https:\/\/www.ammanhardware.com\/en\/products\/bashiti-schneider-00201567","provider":"Amman Hardware stores","version":"1.0","type":"link"}