{"product_id":"bashiti-schneider-00201566","title":"Schneider Acti9 iID K RCCB 40A 2P 30mA A9R50240","description":"\u003cdiv dir=\"ltr\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eSchneider Acti9 iID K RCCB 40A 2P 30mA A9R50240\u003c\/strong\u003e is an option among residual current circuit breakers at Bashiti Stores, designed to detect residual current and trip the circuit when the specified leakage sensitivity is exceeded. This model features a 40A rated current and a 30mA leakage sensitivity. When comparing, distinguish between the current flowing through the device and the leakage value that triggers tripping, and review the appropriate protection type for your loads.\u003c\/p\u003e\n\n\u003ch2\u003ePractical Benefits\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eAdds residual current protection to the protection system when selected and installed correctly.\u003c\/li\u003e\n\n\u003cli\u003eThe presence of a specific rated current and leakage sensitivity allows for clear comparison of the device against panel requirements.\u003c\/li\u003e\n\n\u003cli\u003eDistinguishing between the protection type and current helps avoid confusion between wire protection and leakage protection.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications for this Model\u003c\/h2\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eBrand\u003c\/th\u003e\n\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eSeries\u003c\/th\u003e\n\n\u003ctd\u003eActi9 iID K\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eModel Reference\u003c\/th\u003e\n\n\u003ctd\u003eA9R50240\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eRated Current\u003c\/th\u003e\n\n\u003ctd\u003e40 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\n\u003ctd\u003e2P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Sensitivity\u003c\/th\u003e\n\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Detection Type\u003c\/th\u003e\n\n\u003ctd\u003eAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\n\n\u003ctd\u003e220VAC to 240VAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eDimensions: W x H x D\u003c\/th\u003e\n\n\u003ctd\u003e36 x 85 x 69 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eMounting\u003c\/th\u003e\n\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch2\u003eWho Needs This Product?\u003c\/h2\u003e\n\n\u003cp\u003eDistribution board technicians and installers, when ground fault protection is required according to the protection scheme. The type, sensitivity, current, and number of poles must be selected in coordination with other circuit breakers and loads.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and Verification — For the Specialist Technician\u003c\/h2\u003e\n\n\u003cp\u003eThe following steps outline the general work sequence. Refer to the manufacturer's diagram for reference A9R50240 to determine terminals and connection values. Do not perform work on a live circuit.\u003c\/p\u003e\n\n\u003col\u003e\n\n\u003cli\u003eThe technician disconnects all power sources and locks them out, then verifies the absence of voltage with a suitable tool.\u003c\/li\u003e\n\n\u003cli\u003eMatches the device reference, number of poles, current, and voltage with the panel diagram, and reviews conductor cross-sections and protection coordination.\u003c\/li\u003e\n\n\u003cli\u003eMounts the unit on the DIN rail or designated position after confirming compatibility, and identifies the supply and output from the manufacturer's diagram for this reference.\u003c\/li\u003e\n\n\u003cli\u003eExecutes connections using the torque, stripping length, and wire sizes specified in the model manual; do not reuse these values from a similar device.\u003c\/li\u003e\n\n\u003cli\u003eChecks the integrity of the installation and connections, then closes covers and performs required operation and protection tests before handing over the circuit.\u003c\/li\u003e\n\n\n\u003c\/ol\u003e\n\n\u003ch2\u003eFrequently Asked Questions Before Buying\u003c\/h2\u003e\n\n\u003ch3\u003eDoes an RCCB protect against overload and short circuits?\u003c\/h3\u003e\n\n\u003cp\u003eAn RCCB does not include overcurrent protection; therefore, it requires coordination with a suitable circuit breaker or fuse. It should not be used as a substitute for an overload and short-circuit breaker.\u003c\/p\u003e\n\n\u003ch3\u003eDoes 40A mean the leakage sensitivity is 40A?\u003c\/h3\u003e\n\n\u003cp\u003eNo. The rated current and leakage sensitivity are different values; sensitivity here is in milliamperes, while the rated current concerns the current passing through the device.\u003c\/p\u003e\n\n\u003ch3\u003eIs the AC type suitable for all electronic loads?\u003c\/h3\u003e\n\n\u003cp\u003eNot automatically. The technician determines the required protection type based on the shape of the potential leakage current and the nature of the loads, as some circuits may require a different type.\u003c\/p\u003e\n\n\u003ch2\u003eSchneider at Bashiti Stores — Electrical Department\u003c\/h2\u003e\n\n\u003cp\u003eSelect residual current circuit breakers from the Bashiti electrical department according to the specifications required for your project in Jordan. The series name and reference A9R50240 help you identify the part accurately when inquiring or ordering a replacement. At Bashiti Stores, we provide basic selection data to help you compare similar products, preparing your order for the technician or contractor based on function and compatibility, rather than just price or appearance.\u003c\/p\u003e\n\n\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54699139989777,"sku":"00201566","price":36.54,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/0975\/8481\/files\/00201566.jpg?v=1789809637","url":"https:\/\/www.ammanhardware.com\/en\/products\/bashiti-schneider-00201566","provider":"Amman Hardware stores","version":"1.0","type":"link"}