{"product_id":"bashiti-schneider-00201565","title":"Schneider Acti9 iID K RCCB 25A 2P 30mA A9R50225","description":"\u003cdiv dir=\"ltr\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eSchneider Acti9 iID K 25A 2P 30mA RCCB A9R50225\u003c\/strong\u003e is an option among residual current circuit breakers at Bashiti Stores, designed for monitoring residual current and disconnecting the circuit when the specified leakage sensitivity is exceeded. This model features a 25A current rating and 30mA leakage sensitivity. When comparing, distinguish between the current flowing through the device and the leakage value that triggers disconnection, and verify the appropriate protection type for your loads.\u003c\/p\u003e\n\n\u003ch2\u003ePractical Benefits\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003eAdds residual current detection functionality to the protection system when selected and installed correctly.\u003c\/li\u003e\n\n\u003cli\u003eThe presence of a specific rated current and leakage sensitivity allows for clear comparison of the device with panel requirements.\u003c\/li\u003e\n\n\u003cli\u003eDistinguishing between protection type and current helps avoid confusion between wire protection and leakage protection.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications for this Model\u003c\/h2\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eBrand\u003c\/th\u003e\n\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eSeries\u003c\/th\u003e\n\n\u003ctd\u003eActi9 iID K\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eModel Reference\u003c\/th\u003e\n\n\u003ctd\u003eA9R50225\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eRated Current\u003c\/th\u003e\n\n\u003ctd\u003e25 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\n\u003ctd\u003e2P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Sensitivity\u003c\/th\u003e\n\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eLeakage Detection Type\u003c\/th\u003e\n\n\u003ctd\u003eAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eSpecified Operating Voltage\u003c\/th\u003e\n\n\u003ctd\u003e220VAC to 240VAC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eDimensions: W x H x D\u003c\/th\u003e\n\n\u003ctd\u003e36 x 85 x 69 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eMounting\u003c\/th\u003e\n\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch2\u003eWho Needs This Product?\u003c\/h2\u003e\n\n\u003cp\u003eDistribution board technicians and maintenance staff in buildings, when ground fault protection is required according to the protection scheme. The type, sensitivity, current, and number of poles must be selected in coordination with other breakers and loads.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation and Verification Method — For Professional Technicians\u003c\/h2\u003e\n\n\u003cp\u003eThe following steps outline the general work sequence; the manufacturer's schematic for reference A9R50225 must be followed to determine terminals and torque values. Work must not be performed on a live circuit.\u003c\/p\u003e\n\n\u003col\u003e\n\n\u003cli\u003eThe technician disconnects all power sources and secures them against accidental restart, then verifies the absence of voltage with a suitable tool.\u003c\/li\u003e\n\n\u003cli\u003eMatches the device reference, number of poles, current, and voltage with the panel diagram, and reviews conductor cross-section and protection coordination.\u003c\/li\u003e\n\n\u003cli\u003eMounts the unit on the rail or its designated location after ensuring compatibility, and identifies the supply and load terminals from the manufacturer's schematic for this reference.\u003c\/li\u003e\n\n\u003cli\u003eExecutes connections using the torque, stripping length, and wire gauges specified in the model manual; these values must not be assumed from a similar device.\u003c\/li\u003e\n\n\u003cli\u003eChecks the integrity of the mounting and connections, then closes the covers and performs the required functional and protection tests before handing over the circuit.\u003c\/li\u003e\n\n\u0026gt;\u003c\/ol\u003e\n\n\u003ch2\u003eFrequently Asked Questions Before Purchasing\u003c\/h2\u003e\n\n\u003ch3\u003eDoes an RCCB protect against overload and short circuits?\u003c\/h3\u003e\n\n\u003cp\u003eNo, an RCCB does not include overcurrent protection, so it requires coordination with a suitable circuit breaker or fuse. It is not a substitute for an overload and short-circuit breaker.\u003c\/p\u003e\n\n\u003ch3\u003eDoes 40A mean the leakage sensitivity is 40A?\u003c\/h3\u003e\n\n\u003cp\u003eNo. Rated current and leakage sensitivity are different values; sensitivity here is indicated in milliamperes (mA), while the rated current refers to the current flowing through the device.\u003c\/p\u003e\n\n\u003ch3\u003eIs Type AC suitable for all electronic loads?\u003c\/h3\u003e\n\nNot automatically. The technician determines the required protection type based on the potential leakage current waveform and the nature of the loads; some circuits may require a different type.\n\n\u003ch2\u003eSchneider at Bashiti Stores — Electrical Department\u003c\/h2\u003e\n\n\u003cp\u003eChoose residual current circuit breakers from Bashiti's Electrical Department according to the specifications required for your project in Jordan. The series name and A9R50225 reference help you identify the part accurately when inquiring or requesting a replacement. At Bashiti Stores, we provide essential selection data for you to compare similar products and prepare your order for the technician or contractor based on function and compatibility, rather than just price or appearance.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54699140055313,"sku":"00201565","price":34.13,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/0975\/8481\/files\/00201565.jpg?v=1789809638","url":"https:\/\/www.ammanhardware.com\/en\/products\/bashiti-schneider-00201565","provider":"Amman Hardware stores","version":"1.0","type":"link"}